Public Address and Intercom

Sort By:  
N-8010EX IP Intercom Exchange (economy)
The N-8010EX IP Intercom Exchange uses packet audio technology to permit connection of up to 16 N-8000 series 2-wire master or door stations.
$4,129.20
N-8000RS Sub Station Interface Unit
The N-8000RS Substation Interface Unit uses packet audio technology to permit connection of up to 16 RS-1xx series call switches or door stations.
$3,000.00
N-8000RS Adapter
Converts the output signal of the interface unit into a line level audio signal or a 25V line speaker output
$391.50
The IP-A1PC580S is a PoE-powered Surface mount Speaker with a built-in 8W amplifier and internal data storage for up to 20 audio files.
$575.00
Audio Interface Unit
The N-8000AF provides either an analog audio input/output bridge to the N-8000 system, a bell schedule generator with internal tones, or record functionality for archival purposes.
$1,546.00
Central Office Interface Unit
The N-8000CO is a C/O interface unit designed for use with TOA's packet intercom system (IP network-compatible intercom system) that employs the packet audio technology. It has an analog central office line circuit, allowing the intercom station to make and receive calls to and from the telephone line.
$1,755.30
Direct Selection Unit
The N-8000DI is a Direct select unit designed for use with TOA's packet intercom system (IP network-compatible intercom system) that employs the packet audio technology. It is equipped with each 32 contact inputs and outputs, and the indicators on the front panel indicate the output statuses.
$2,098.00
Multi-Interface (BGM, TEL, EXES, Control I/O)
The N-8000MI is a multisource interface for the N-8000 intercom system.
$2,697.00
Handsfree Master Station
The N-8011MS is a hands-free master station that connects to an N-8000EX or N-8010EX intercom exchange by a single twisted pair wire.
$373.50
Panel-Mount Master Station PCB
The N-8031SB is a PCB kit version of the N-8031MS for custom installations where a custom interface is desired. It connects to an N-8000EX or N-8010EX exchange by a single twisted pair cable.
$270.50
Call/Privacy Switch Station
The RS-140 dual button call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces. It provides Call (Red) and Privacy (white) buttons.
$85.00
Substation PCB
The N-8050SB is a printed circuit board unit for the N-8050DS Door Station, You can make the sub station suitable for applications using the N-8050SB in combination with the operation panel section to be prepared separately.
$263.30
Indoor Substation
Designed to connect to the IP Intercom Exchange, the N-8050DS is a door station featuring high quality hands-free conversation. It has a contact output (momentarily closed) to remotely control an electronic door lock.
$472.70
Q-N8050WP Outdoor Substation
The Q-N8050WP is a weather resistant door station designed to connect to an N-8000EX or N-8010EX intercom exchange. It provides high quality, hands-free conversation with a master station on an N-8000 system.
$606.10
Standard Master Station
The N-8010MS is a standard master station (no LCD display) that connects to an N-8000EX or N-8010EX intercom exchange by a single twisted pair wire.
$0.00
2-Gang Indoor Substation
The N-8052DS is a 2-gang version of the N-8050DS. It is a door station designed to connect to an N-8000EX or N-8010EX intercom exchange.
$479.90
Multifunction Master Station
The N-8000MS is a multi-function master station that connects to an N-8000EX or N-8010EX intercom exchange by a single twisted pair wire.
$745.10
Panel-Mount Master Station
The N-8031MS is a flush- or surface-mount master station designed to operate in conjunction with TOA IP Intercom Exchange and features high quality hands-free conversation.
$535.90
Call/Emergency Switch Station
The RS-144 dual button call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces.  It provides Emergency (Red) and Normal (white) buttons that can be individually programmed to report to any master station based on job specification.
$96.50
Indoor Vandal Resistant Remote Sub-Station
The RS-160 vandal resistant single button indoor call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces.
$0.00
N-8010EX IP Intercom Exchange (economy)
N-8010EX IP Intercom Exchange (1 Voice Link) (N-8010EX)

The N-8010EX IP Intercom Exchange uses packet audio technology to permit connection of up to 16 N-8000 series 2-wire master or door stations. Master stations and door stations use the same unshielded twisted pair wiring. Each N-8010EX supports one voice link. The N-8010EX supports the audio trigger function. The exchange may be used as a stand-alone system (requires at least one master station) or connected to an N-8000 IP intercom system over LAN or WAN. Rack mount and wall mount hardware are included

The latest software version is 4.2.2 (update:2020/6/18), with previous versions 4.2.0(update:2015/04/03), 4.10(update:2014/11/13),and 1.41(update:2008/10/06). The Maintenance Software(Ver.1.2.0) is used to monitor or maintain equipment within the system(upload:2015/04/03).

Power Source 120 V AC, 50/60 Hz
Power Consumption 35 W (at rated), 45 W (max.)
Interface Section for Sub-station Number of lines: 16 lines
Number of speech link: 2 links
Transmission system: Analog baseband
Transmission range: 500 m (546.81 yd)/φ0.5 mm (AWG24), 800 m (874.89 yd)/
Speech method: Half-duplex conversation by way of voice switch
Connector: Removable terminal block (3 pins)
Wiring method: Two-core shielded cable
Audio output: Max. 1 W/line (conversation), Max. 0.5 W/line (paging)
Feeding voltage/current: 22 V DC, 30 mA max.
Control signal: Call in button detection, privacy button detection, hook detection
Network Section Network I/F: 10BASE-T/100BASE-TX (Automatic-Negotiation)
Network protocol: TCP/IP, UDP, HTTP, RTP, ARP, ICMP, IGMP
Audio packet transmission system: Unicast, Multicast
Number of paging destinations: 0, *Reception only
Connector: RJ45 connector
Voice sampling frequency: 16 kHz, 8 kHz (controllable on the software)
Quantifying bit number: 16-bit
Voice encoding method: Sub-band ADPCM, Cryptosystem
Voice packet loss recovery: Silence insertion
Audio delay time: 80 ms, 320 ms (controllable on the software)
Indication Network LNK/ACT indication, Status lamp, Power-on indication lamp
Other Firmware update function, System data hold function, Reset switch (front panel),
Forced air cooling
Setting Method Rack, Desk, Surface mount
Operating Temperature 0 ℃ to 40 ℃ (32 ゜F to 104 ゜F)
Operating Humidity 90 %RH or less (no condensation)
Finish Pre-coated steel plate, black, 30 % gloss
Dimensions 420 (W) × 44.3 (H) × 325.5 (D) mm (16.54" × 1.74" × 12.81")
Weight 3.9 kg (8.6 lb)
Accessory Power cord (2 m (6.56 ft)) …1, CD (for PC setting, maintenance use) …1,
Removable terminal plug (3 pins) …16, Plastic foot …4, Screw for fitting plastic foot …4,
Rack mounting bracket …2, Screw for mounting bracket …8, Screw for rack mounting …4
Option Wall mounting bracket: YC-850
The N-8010EX IP Intercom Exchange uses packet audio technology to permit connection of up to 16 N-8000 series 2-wire master or door stations.
$4,129.20
N-8000RS Sub Station Interface Unit
N-8000RS Sub Station Interface Unit (N-8000RS)

The N-8000RS Substation Interface Unit uses packet audio technology to permit connection of up to 16 RS-1xx series call switches or door stations. Call switches and door stations use the same shielded twisted pair wiring. Each port provides 1W @25V to a door station, or 25V loudspeaker attached to a call switch. Each N-8000RS supports 2 voice links. The N-8000RS requires an IP master station, or connection to a 2-wire or 4-wire Exchange with at least one master station on the exchange.

The N-8000RS Substation Interface Unit uses packet audio technology to permit connection of up to 16 RS-1xx series call switches or door stations.
$3,000.00
N-8000RS Adapter
N-8000RS Adapter (Q-N8000LC AM)

Accessory adapter for N-8000RS or N-8010RS, N-8000 Substation Interface Unit Converts the output signal of the interface unit into a line level audio signal or a 25V line speaker output Equipped with four channel outputs with level selection switch 2.72"(w) x 1.54"(h) x 1.10"(d)* (69 x 39 x 28mm*) *Not including output connectors.

Converts the output signal of the interface unit into a line level audio signal or a 25V line speaker output
$391.50
Square IP Speaker (IP-A1PC580S)

The IP-A1PC580S is a PoE-powered Surface mount Speaker with a built-in 8W amplifier and internal data storage for up to 20 audio files. It supports SIP protocol for flexible integrations with VoIP devices, and its 20 multicast ports are available for group paging operations. It can also receive broadcasts from Video Management System via ONVIF audio backchannel. Device control and further system integration is accessed through remote API (HTTP) or local control inputs.

The IP-A1PC580S is a PoE-powered Surface mount Speaker with a built-in 8W amplifier and internal data storage for up to 20 audio files.
$575.00
Audio Interface Unit
Audio Interface Unit (N-8000AF)

The N-8000AF provides either an analog audio input/output bridge to the N-8000 system, a bell schedule generator with internal tones, or record functionality for archival purposes. It can also function as the system master clock, with sync to contact closure or NTP server as required. When used as an analog audio bridge to the N-8000 intercom system, it accepts one mic or line level input which can be broadcast to any paging zone or station on the system. One line-level output is provided, with eight contact closure inputs and eight contact closure outputs. Contact closures may be synchronized with a paging event. When used as a bell schedule generator, the N-8000AF provides 16 schedules with 64 events per schedule. Five internal tones are available, with the option to trigger up to four external paging sources. When used as for recording it provides an analog audio output and contact closure control for external recording devices to record pages, announcements, and conversations. Rack mount kit not included. Use TOA MB-15B-BK (one unit per rack space) or MB-15B-J (two units per rack space).

Power Source 120 V AC, 50/60 Hz
Power Consumption 7 W (max.)
Audio Input 1 input (transformer isolated), -58 dB* to 0 dB*, 2 kΩ, balanced
(MIC/LINE input, controllable on the software)
with input volume control knob, removable terminal block (3 pins)
Audio Output 1 output (transformer isolated), 0 dB*, 600 Ω, balanced, removable terminal block (3 pins)
Contact Input 8 inputs, no-voltage make contact input, open voltage: 24 V DC,
short-circuit current: 5 mA or less, removable terminal block (10 pins),
(1 common terminal for 4 inputs)
Contact Output 8 outputs, relay contact output, contact capacity: 24 V DC/2 - 500 mA,
removable terminal block (16 pins)
Time Sync Input 1 input, no-voltage make contact input, open voltage: 24 V DC,
short-circuit current: 5 mA or less, removable terminal block (2 pins)
Network Section Network I/F: 10BASE-T/100BASE-TX (Automatic-Negotiation)
Network protocol: TCP/IP, UDP, HTTP, RTP, ARP, ICMP, IGMP
Audio packet transmission system: Unicast, Multicast
Number of paging destinations: Unicast (max. 8), Multicast (max. 191)
Connector: RJ45 connector
Voice sampling frequency: 16 kHz, 8 kHz (controllable on the software)
Quantifying bit number: 16-bit
Voice encoding method: Sub-band ADPCM, Cryptosystem
Voice packet loss recovery: Silence insertion
Audio delay time: 80 ms, 320 ms (controllable on the software)
Indication Network LNK/ACT indication, Status lamp, Power-on indication lamp, Signal lamp, Peak lamp
Other Firmware update function, System data hold function, Time of day hold facility,
Reset switch (front panel)
Setting Method Rack, Desk, Surface mount
Operating Temperature 0 ℃ to 40 ℃ (32 ゜F to 104 ゜F)
Operating Humidity 90 %RH or less (no condensation)
Finish Pre-coated steel plate, black, 30 % gloss
Dimensions 210 (W) × 44.3 (H) × 267 (D) mm (8.27" × 1.74" × 10.51")
Weight 1.7 kg (3.75 lb)
Accessory Power cord (2 m (6.56 ft)) …1, CD (for PC setting, maintenance use) …1,
Removable terminal plug (2 pins) …1, Removable terminal plug (3 pins) …2,
Removable terminal plug (5 pins) …2, Removable terminal plug (8 pins) …2,
Plastic foot…4, Screw for fitting plastic foot …4
Option Rack mounting bracket: MB-15B-BK (for rack mounting one N-8000AF unit)
MB-15B-J (for rack mounting two N-8000AF units)
Wall mounting bracket: YC-850
The N-8000AF provides either an analog audio input/output bridge to the N-8000 system, a bell schedule generator with internal tones, or record functionality for archival purposes.
$1,546.00
Central Office Interface Unit
Central Office Interface Unit (N-8000CO)

The N-8000CO is a C/O interface unit designed for use with TOA's packet intercom system (IP network-compatible intercom system) that employs the packet audio technology. It has an analog central office line circuit, allowing the intercom station to make and receive calls to and from the telephone line. Connecting the unit to the LAN permits paging calls through analog subscriber line to be made and the equipment connected to the N-8000MI and N-8000DI to be controlled. It can be mounted in an EIA equipment rack (1U size) with the use of an optional rack mounting bracket or installed on a wall using an optional wall mounting bracket. Rack mount kit not included. Use TOA MB-15B-BK (one unit per rack space) or MB-15B-J (two units per rack space)

Power Source 120 V AC, 50/60 Hz
Power Consumption 7 W (max.)
C/O Interface Public Switched telephone networks
Number of lines: 1 line
Selective signal type: DTMF signal
Signal system: Compatible with loop start signaling
Wiring method: 1 pair of twisted pair cables
Network Section Network I/F: 10BASE-T/100BASE-TX (Automatic-Negotiation)
Network protocol: TCP/IP, UDP, HTTP, RTP, ARP, ICMP, IGMP
Audio packet transmission system: Unicast, Multicast
Number of paging destinations: Unicast (max. 8), Multicast (max. 191)
Connector: RJ45 connector
Voice sampling frequency: 16 kHz, 8 kHz (controllable on the software)
Quantifying bit number: 16-bit
Voice encoding method: Sub-band ADPCM, Cryptosystem
Voice packet loss recovery: Silence insertion
Audio delay time: 80 ms, 320 ms (controllable on the software)
Indication Network LNK/ACT indication, Status lamp, Power-on indication lamp,
Line in-use lamp
Other Firmware update function, System data hold function, Time of day hold facility,
Reset switch (front panel)
Setting Method Rack, Desk, Surface mount
Operating Temperature 0 ℃ to 40 ℃ (32 ゜F to 104 ゜F)
Operating Humidity 90 %RH or less (no condensation)
Finish Pre-coated steel plate, black, 30 % gloss
Dimensions 210 (W) × 44.3 (H) × 267 (D) mm (8.27" × 1.74" × 10.51")
Weight 1.7 kg (3.75 lb)
Accessory Power cord (2 m (6.56 ft)) …1, CD (for PC setting, maintenance use) …1,
Mini-clamp plug (2 pins) …2, Plastic foot …4, Screw for fitting plastic foot …4
Option Rack mounting bracket: MB-15B-BK (for rack mounting one N-8000CO unit)
MB-15B-J (for rack mounting two N-8000CO units)
Wall mounting bracket: YC-850
The N-8000CO is a C/O interface unit designed for use with TOA's packet intercom system (IP network-compatible intercom system) that employs the packet audio technology. It has an analog central office line circuit, allowing the intercom station to make and receive calls to and from the telephone line.
$1,755.30
Direct Selection Unit
Direct Selection Unit (N-8000DI)

The N-8000DI is a Direct select unit designed for use with TOA's packet intercom system (IP network-compatible intercom system) that employs the packet audio technology. It is equipped with each 32 contact inputs and outputs, and the indicators on the front panel indicate the output statuses. Connecting the unit to the LAN permits the calling station display, external equipment control, and direct selection function to be realized. It can be mounted in an EIA equipment rack (1U size) with the use of an accessory rack mounting bracket or installed on a wall using an optional wall mounting bracket. Rack mount and wall mount hardware included.

Power Source 120 V AC, 50/60 Hz
Power Consumption 16 W (max.)
Contact Input 32 inputs, no-voltage make contact input, open voltage: 24 V DC,
short-circuit current: 5 mA or less, removable terminal block (20 pins)
(1 common terminal for 4 inputs)
Contact Output 32 outputs, relay contact output, contact capacity: 24 V DC/2 - 500 mA,
removable terminal block (32 pins)
Network Section Network I/F: 10BASE-T/100BASE-TX (Automatic-Negotiation)
Network protocol: TCP/IP, UDP, HTTP, RTP, ARP, ICMP, IGMP
Connector: RJ45 connector
Indication Network LNK/ACT indication, Status lamp, Power-on indication lamp,
Channel indication lamps (32 channels)
Other Firmware update function, System data hold function, Time of day hold facility,
Reset switch (front panel)
Setting Method Rack, Desk, Surface mount
Operating Temperature 0 ℃ to 40 ℃ (32 ゜F to 104 ゜F)
Operating Humidity 90 %RH or less (no condensation)
Finish Pre-coated steel plate, black, 30 % gloss
Dimensions 420 (W) × 44.3 (H) × 267 (D) mm (16.54" × 1.74" × 10.51")
Weight 2.8 kg (6.17 lb)
Accessory Power cord (2 m (6.56 ft)) …1, CD (for PC setting, maintenance use) …1,
Removable terminal plug (10 pins) …4, Removable terminal plug (16 pins) …4,
Plastic foot …4, Screw for fitting plastic foot …4, Rack mounting bracket …2,
Screw for mounting bracket …8, Screw for rack mounting …4
Option Wall mounting bracket: YC-850
The N-8000DI is a Direct select unit designed for use with TOA's packet intercom system (IP network-compatible intercom system) that employs the packet audio technology. It is equipped with each 32 contact inputs and outputs, and the indicators on the front panel indicate the output statuses.
$2,098.00
Multi-Interface (BGM, TEL, EXES, Control I/O)
Multi-Interface (BGM, TEL, EXES, Control I/O) (N-8000MI)

The N-8000MI is a multisource interface for the N-8000 intercom system. When used as an analog audio bridge to the N-8000 intercom system, it accepts two line-level inputs which can be broadcast to any paging zone or station on the system. Two line-level outputs are provided, with sixteen contact closure inputs and sixteen relay outputs. Contact closures may be synchronized with a paging event, linked to contact closure inputs, be triggered by a station call, be triggered by IP control or a master station, or be triggered by a fault in the network or a 2-wire (N-8000EX/N-8010EX) line fault for 24/7 supervision. Rack mount and wall mount hardware included

table id="spectable"> Power Source 120 V AC, 50/60 Hz Power Consumption 16 W (250 mA) (at rated), 21 W (330 mA) (max.) Audio Input (*3) Input: 2 inputs (2 P/input), Max. 0 dB (*1), 600 Ω or less, balanced,
with a semi-fixed volume for adjustment (0 to -25 dB)
Control: 2 inputs (2 P/input), no-voltage make contact input, open voltage: 12 V DC,
short-circuit current: 10 mA
Removable terminal block (8 pins) Audio Output (*3) Output: 2 outputs (2 P/output), Max. 0 dB (*1), 600 Ω or less, balanced
Control: 2 outputs (2 P/output), relay contact output, contact capacity: 24 V DC/0.5 A
Removable terminal block (8 pins) Contact Input (*3) 16 inputs, no-voltage make contact input, open voltage: 12 V DC,
short-circuit current: 10 mA, removable terminal block (18 pins) Contact Output (*3) 16 outputs, relay contact output, contact capacity: 24 V DC/0.5 A,
removable terminal block (18 pins) PBX I/F (*3) PBX input and output: 2 channels, Max.: 0 dB (*2) or less, Average: -15 dB (*2) or less,
600 Ω, balanced, mini-clamp connector (2 pins),
with adjustment functions for both input and output
(Input: 0 to 15 dB, Output: -15 to 0 dB), Analog E & M interface Tie-line I/F (*3) Tie-line input and output: 2 channels, Max.: 0 dB (*2) or less, Average: -15 dB (*2) or less,
600 Ω, balanced, mini-clamp connector (2 pins)
Signal method: EXES-2000/EXES-6000 tie-line method
Selective signal: DTMF signal Network Section Network I/F: 10BASE-T/100BASE-TX (Automatic-Negotiation)
Network protocol: TCP/IP, UDP, HTTP, RTP, ARP, ICMP, IGMP
Audio packet transmission system: Unicast, Multicast
Number of paging destinations: Unicast (max. 16), Multicast (max. 191)
Connector: RJ45 connector
Voice sampling frequency: 16 kHz, 8 kHz (controllable on the software)
Quantifying bit number: 16-bit
Voice encoding method: Sub-band ADPCM, Cryptosystem
Voice packet loss recovery: Silence insertion
Audio delay time: 80 ms, 320 ms (controllable on the software) Indication Network LNK/ACT indication, Status lamp, Power-on indication lamp Others Firmware update function, System registration data entry hold facility,
Time of day hold facility, Reset switch (front panel) Installation Method Rack, Desk, Surface mount Operating Temperature 0 ℃ to 40 ℃ Operating Humidity 90 %RH or less (no condensation) Finish Pre-coated steel plate, black, 30 % gloss Dimensions 420 (W) × 44.3 (H) × 239.5 (D) mm Weight 2.8 kg Accessory AC power cord (2 m) …1, CD (for PC setting, maintenance use) …1,
Mini-clamp plug (2 pins) …10, Removable terminal plug (8 pins) …2,
Removable terminal plug (9 pins) …4, Plastic foot …4, Screw for fitting plastic foot …4,
Rack mounting bracket …2, Screw for rack mounting …4, Wall mounting bracket …2,
Screw for mounting bracket …8, Screw for wall mounting …4
The N-8000MI is a multisource interface for the N-8000 intercom system.
$2,697.00
Handsfree Master Station
Handsfree Master Station (N-8011MS)

The N-8011MS is a hands-free master station that connects to an N-8000EX or N-8010EX intercom exchange by a single twisted pair wire. It is capable of full duplex hands-free communication with other full duplex stations. The N-8011MS master This Master Station is designed to connect to the IP Intercom Exchange, and provides hands-free conversation of high sound quality. With its space-saving design, this Master Station features the same functions as the Standard Master Station. This station can be mounted to the wall using an optional YC-290 wall mounting bracket.

Power Source 48 V DC (supplied from the IP intercom exchange (option))
Power Consumption 1.8 W (at rated), 2.4 W (max.)
Wiring Method 1 set of twisted pair cable
Transmission System 2 wire 160 kbps echo canceller transmission system
Signal Level Under 0 dB*
Speech Method Hands-free conversation
Audio Frequency Range 300 Hz - 7 kHz
Transmission Range Max. 1500 m (φ0.65 mm, Loop resistance 170 Ω)
Hands-free Speaker: 5.7 cm cone-type, 0.6 W, 8 Ω
Microphone: Omni-directional electret condenser microphone
Indication Status lamp
Line Connecting Terminal RJ11 modular jack
Installation Method Desk/Surface mounted master station
(When mounting to the wall, use the optional YC-290.)
Operating Temperature 0 ℃ to 40 ℃
Operating Humidity Under 90 % RH (no condensation)
Finish Body: ABS resin, gray
Dimensions 92 (W) x 195 (H) x 56.1 (D) mm
Weight 400 g
Accessory Connection cord (3 m) …1
Option Wall mounting bracket: YC-290
The N-8011MS is a hands-free master station that connects to an N-8000EX or N-8010EX intercom exchange by a single twisted pair wire.
$373.50
Panel-Mount Master Station PCB
Build-Your-Own Intercom Master Station PCB (N-8031SB)

The N-8031SB is a PCB kit version of the N-8031MS for custom installations where a custom interface is desired. It connects to an N-8000EX or N-8010EX exchange by a single twisted pair cable. Connecting a foot switch or other external switch to the external dial input terminal permits one-touch dialing when activated. This equipment is compatible with the RS-191 handset for private conversation.

Power Source 48 V DC (supplied from the IP intercom exchange (option))
Power Consumption 1.8 W (at rated), 2.4 W (max.)
Wiring Method Non-polar one pair stranded wire system
Transmission System 2 wire 160 kbps echo canceller transmission system
Signal Level Under 0 dB*
Speech Method Hands-free conversation
(Handset conversation can be established in conjunction with the RS-191 (option)).
Audio Frequency Range 300 - 7,000 Hz
Transmission Range Max. 1500 m (φ0.65 mm, Loop resistance 170 Ω)
Hands-free Speaker (accessory): 5.7 cm cone-type, 0.6 W, 8 Ω
Microphone (accessory): Omni-directional electret condenser microphone
Line Connection Terminal Pin header (2 pins)
Status Indicator LED Connecting Terminal Solderless connector (2 pins, male), voltage: 5 V, maximum load current: 5 mA
Dial Input Solderless connector (10 pins, male), open voltage: 3.3 V DC,
short-circuit current: 1 mA
External Dial Input No-voltage make contact input, open voltage: 5 V DC,
short-circuit current: 1 mA, screwless connector (5 pins)
Operation Temperature 0℃ to 40℃
Operation Humidity Under 90% RH (no condensation)
Dimensions 70 (W) × 185 (H) × 20.6 (D) mm
Weight 205 g (including accessories)
Accessory Removable terminal plug (2 pins, preinstalled on the unit) …1,
Handset jumper (8 pins, preinstalled on the unit) …1, Ferrite clamp …1,
Hands-free speaker (with connection cord) …1,
Hands-free microphone (with connection cord) …1
Option Option handset: RS-191
The N-8031SB is a PCB kit version of the N-8031MS for custom installations where a custom interface is desired. It connects to an N-8000EX or N-8010EX exchange by a single twisted pair cable.
$270.50
Call/Privacy Switch Station
Call/Privacy Switch Station (RS-140)
The RS-140 dual button call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces. It provides Call (Red) and Privacy (white) buttons. The call button can be programmed to report to any master station based on job specification. Additionally both buttons have individual LED indicators to show when the button is active. It requires 3-conductor shielded twisted pair (STP) wiring and mounts in a standard US single gang flush or wall mount box. The optional RS-141 handset for private calling, or a 25V/1W speaker such as the PC-580RU for room announcement applications, can be connected to the call panel station.
The RS-140 dual button call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces. It provides Call (Red) and Privacy (white) buttons.
$85.00
Substation PCB
Build-Your-Own Intercom Sub-Station PCB (N-8050SB)

The N-8050SB is a printed circuit board unit for the N-8050DS Door Station, You can make the sub station suitable for applications using the N-8050SB in combination with the operation panel section to be prepared separately.

Power Source 48 V DC (supplied from the IP intercom exchange (option))
Power Consumption 1.8 W (at rated), 2.4 W (max.)
Wiring Method Non-polar one pair stranded wire system
Transmission System 2 wire 160 kbps echo canceller transmission system
Signal Level Under 0 dB*
Speech Method Hands-free conversation
Audio Frequency Range 300 - 7,000 Hz
Transmission Range Max. 1500 m (φ0.65 mm, Loop resistance 170 Ω)
Hands-free Speaker (accessory): 3.5 cm cone-type, 1 W, 8 Ω
Microphone (accessory): Omni-directional electret condenser microphone
Contact Output Open collector output, withstand voltage: Max. 30 V DC, control current: Max. 50 mA
one shot: can be set from 1 to 9 sec, screw terminal (polarized)
Line Connection Terminal 2 wire, screw terminal (non-polar)
Status Indicator LED Connecting Terminal Solderless connector (5 pins, male), voltage: 5 V, maximum load current: 4.1 mA
Call Button Connecting Terminal Solderless connector (5 pins, male), open voltage: 3.3 V DC,
short-circuit current: 1.5 mA
Operation Temperature -10℃ to 50℃
Operation Humidity Under 90% RH (no condensation)
Dimensions 67 (W) × 128.3 (H) × 26 (D) mm
Weight 100 g (including accessories)
Accessory Hands-free speaker (with connection cord) …1,
Hands-free microphone (with connection cord) …1
The N-8050SB is a printed circuit board unit for the N-8050DS Door Station, You can make the sub station suitable for applications using the N-8050SB in combination with the operation panel section to be prepared separately.
$263.30
Indoor Substation
Indoor Sub-Station (N-8050DS)

Designed to connect to the IP Intercom Exchange, the N-8050DS is a door station featuring high quality hands-free conversation. It has a contact output (momentarily closed) to remotely control an electronic door lock. It is in full conformity with IP54 water-proof and dust-proof standards. The operating temperature range is -10 to 50℃. As provided with guard nets inside to cover over the openings of microphone and speaker, the N-8050DS can be installed free from care in public space.

Power Source 48 V DC (supplied from the IP intercom exchange (option))
Power Consumption 1.8 W (at rated), 2.4 W (max.)
Wiring Method 1 set of twisted pair cable
Transmission System 2 wire 160 kbps echo canceller transmission system
Signal Level Under 0 dB*
Speech Method Hands-free conversation
Audio Frequency Range 300 Hz - 7 kHz
Transmission Range Max. 1500 m (φ0.65 mm. Loop resistance 170 Ω)
Hands-free Speaker: 3.5 cm cone-type, 1 W, 8 Ω
Microphone: Omni-directional electret condenser microphone
Contact Output Open collector output, withstand voltage: Max. 30 V DC,
control current: Max. 50 mA, one shot: can be set from 1 to 9 s,
screw terminal (polarized)
Indication Status lamp
Line Connecting Terminal 2 wire, screw terminal (non-polar)
Setting Method Flush-mount/Surface-mount
Operating Temperature -10 ℃ to 50 ℃
Operating Humidity Under 90 % RH (no condensation)
Housing Protection BS EN62262: 2002: IK02 equivalent
Dust/Water Protection IP54 (Note that panel edges must be sealed at installation.)
Finish Plate: Stainless steel (SUS304), hairline
Call button: Metal
Dimensions 115 (W) x 162 (H) x 54 (D) mm
Weight 680 g
Accessory Box mounting screw (No.6-32UNC × 18) …4,
Box mounting screw (M4 × 25) …4, Acoustic absorbent (made of felt) …1
Applicable Box (option) For flush mount: 3-gang electrical box or Back Box YC-150
For wall mount: Wall-mount Box YS-13A
Designed to connect to the IP Intercom Exchange, the N-8050DS is a door station featuring high quality hands-free conversation. It has a contact output (momentarily closed) to remotely control an electronic door lock.
$472.70
Q-N8050WP Outdoor Substation
Q-N8050WP Outdoor Sub-Station (Q-N8050WP)

The Q-N8050WP is a weather resistant door station designed to connect to an N-8000EX or N-8010EX intercom exchange. It provides high quality, hands-free conversation with a master station on an N-8000 system. The Q-N8050WP is IP54 rated with additional protection for the PCB It includes a remote controllable open collector control output (momentary 1-9 seconds). The Q-N8050WP supports the audio trigger function. Requires 3-gang back box.

Power Source 48 V DC (Supplied from the IP Intercom exchange (option))
Power Consumption 1.8 W (at rated), 2.4 W (max.)
Wiring Method Non-polar one pair straned wire system
Transmission System 2 wire 160 kbps echo canceller transmission system
Signal Level Under 0 dB*
Speech Method Hands-free conversation
Audio Frequency Range 300 - 7,000 Hz
Transmission Range Max. 1500 m (⌀0.65 mm. Loop resistance 170Ω)
Hands-free Speaker: 3.5cm cone-type, 1W, 8 Ω
Microphone: Omni-directional electret condenser microphone
Contact Output Open collector output, withstand voltage: Max. 30 V DC, control current: Max. 50 mA, one shot: can be set from 1 to 9 s, scre terminal (polarized)
Line Connecting Terminal 2 wire, scre terminal (non-polar)
Settting Method Flush-mount / Surface-mount
Operating Temperature -10° to 50°C (14° to 122°F)
Operating Humidity Under 90% RH (no condensation)
Housing Protection BS EN62262: 2002: IK02 equivalent
Dust / Water Protection IP 54 (note that panel edges must be sealed at installation.)
Resistance to Environment Pass our gas corrosion test and neutral salt spray test
Finish Plate: Stainless steel (SUS304), hairline
Call button: Metal
Circuit board: Silicone sealing agent-coated board
Dimensions 115 (W) x 162 (H) x 54 (D) mm (4.53" x 6.38" x 2.13")
Weight 680g (1.5 lbs)
Accessory Box mounting screw (No. 6 - 32 UNC x 18)...4, Box mounting screw (M4 x 25)...4
Applicable Box (Option) For flush mount: 3-gang electrical box or Back Box YC-150
For wll mount: Wall-mount Box YS-13A
The Q-N8050WP is a weather resistant door station designed to connect to an N-8000EX or N-8010EX intercom exchange. It provides high quality, hands-free conversation with a master station on an N-8000 system.
$606.10
Standard Master Station
Standard Master Station (N-8010MS)

The N-8010MS is a standard master station (no LCD display) that connects to an N-8000EX or N-8010EX intercom exchange by a single twisted pair wire. It is capable of full duplex hands-free or handset communication with other full duplex stations. The N-8010MS master station may be wall or desk mounted.

Power Source 48 V DC (supplied from the IP intercom exchange (option))
Power Consumption 1.8 W (at rated), 2.4 W (max.)
Wiring Method 1 set of twisted pair cable
Transmission System 2 wire 160 kbps echo canceller transmission system
Signal Level Under 0 dB*
Speech Method Hands-free or handset conversation
Audio Frequency Range 300 Hz - 7 kHz
Transmission Range Max. 1500 m (φ0.65 mm, Loop resistance 170 Ω)
Hands-free Speaker: 5.7 cm cone-type, 0.6 W, 8 Ω
Microphone: Omni-directional electret condenser microphone
Handset Receive path: Dynamic type
Send path: Electret condenser microphone
Indication Status lamp
Line Connecting Terminal RJ11 modular jack
Installation Method Desk/Surface mounted master station
(When mounting to the wall, use the optional YC-280.)
Operating Temperature 0 ℃ to 40 ℃
Operating Humidity Under 90 % RH (no condensation)
Finish Body, Handset: ABS resin, gray
Dimensions 148 (W) x 208 (H) x 70.5 (D) mm (excluding a curl cord section)
Weight 700 g
Accessory Connection cord (3 m) …1
Option Wall mounting bracket: YC-280
The N-8010MS is a standard master station (no LCD display) that connects to an N-8000EX or N-8010EX intercom exchange by a single twisted pair wire.
$0.00
2-Gang Indoor Substation
2-Gang Indoor Sub-Station (N-8052DS)

The N-8052DS is a 2-gang version of the N-8050DS. It is a door station designed to connect to an N-8000EX or N-8010EX intercom exchange. It provides high quality, hands-free conversation with a master station on an N-8000 system. The N-8052DS includes a remote controllable open collector control output (momentary 1-9 seconds). The N-8052DS supports the audio trigger function.

Power Source 48 V DC (supplied from the IP intercom exchange (option))
Power Consumption 1.8 W (at rated), 2.4 W (max.)
Wiring Method 1 set of twisted pair cable
Transmission System 2 wire 160 kbps echo canceller transmission system
Signal Level Under 0 dB*
Speech Method Hands-free conversation
Audio Frequency Range 300 Hz - 7 kHz
Transmission Range Max. 1500 m (φ0.65 mm. Loop resistance 170 Ω)
Hands-free Speaker: 3.5 cm cone-type, 1 W, 8 Ω
Microphone: Omni-directional electret condenser microphone
Contact Output Open collector output, withstand voltage: Max. 30 V DC,
control current: Max. 50 mA, one shot: can be set from 1 to 9 s,
screw terminal (polarized)
Line Connecting Terminal 2 wire, screw terminal (non-polar)
Setting Method Flush-mount/Surface-mount
Operating Temperature -10 ℃ to 50 ℃
Operating Humidity Under 90 % RH (no condensation)
Housing Protection BS EN62262: 2002: IK02 equivalent
Finish Plate: Stainless steel (SUS304), hairline
Call button: Metal
Dimensions 120 (W) x 120 (H) x 50.5 (D) mm
Weight 525 g
Accessory Box mounting screw (No.6-32UNC × 18) …4,
Box mounting screw (M4 × 25) …4, Acoustic absorbent (made of felt) …1
Applicable Box (option) For flush mount: 3-gang electrical box or Back Box YC-302 (option)
For wall mount: Wall-mount Box YC-822 (option)
The N-8052DS is a 2-gang version of the N-8050DS. It is a door station designed to connect to an N-8000EX or N-8010EX intercom exchange.
$479.90
Multifunction Master Station
Multifunction Master Station (N-8000MS)

The N-8000MS is a multi-function master station that connects to an N-8000EX or N-8010EX intercom exchange by a single twisted pair wire. It is capable of full duplex hands-free or handset communication with other full duplex stations. It includes an Alpha-numeric LCD display, one-touch dialing, headset connection and an external speaker connection (.6 W @ 8Ω). External or internal speaker priority is supported. The master station may be wall or desk mounted.

Power Source 48 V DC (supplied form the IP intercom exchange (options))
Power consumption 1.8 W (at rated), 2.4 W (max.)
Wiring Method 1 set of twisted pair cable
Transmission System 2 wire 160 kbps echo canceller transmission system
Signal Level 0 dB* or less
Speech Method Hands-free or handset conversation
Audio Frequency Range 300 Hz - 7 kHz
Transmission Range Max. 1500 m (φ0,65 mm, loop resistance 170 Ω)
Hands-free

Speaker: 5.7 cm cone-type, 0,6 W, 8 Ω
Microphone : omni-directional electret condenser microphone

Handset Receive path: Dynamic type
Send path: Electret condenser microphone
Display LCD: Alphanumeric characters (16 characters x 2 lines)
Indication Status lamp
Line Connecting Terminal RJ11 modular jack
Headset Terminal Spaker: 3 mW, 32 Ω; microphone : -49 dB*, φ3,5 mm mini jack
External Speaker Terminal 0.6 W, 8 Ω, screwless connector (2 pins)
Installation Method Desk/Surface mounted master station (when mounted to the wall, use the optional YC-281.)
Operating Temperature 0 ℃ to 40 ℃
Operating Humidity 90% RH or less (no condensation)
Finish Body, Hndset: ABS resin, gray
Dimensions 148 (W) x 208 (H) x 69.7 (D) mm (excluding a curl cord section)
Weight 800 g
Accessory Connection cord (3 m) x 1
Option Wall mounting bracket: YC-280
The N-8000MS is a multi-function master station that connects to an N-8000EX or N-8010EX intercom exchange by a single twisted pair wire.
$745.10
Panel-Mount Master Station
Panel-Mount Master Station (N-8031MS)

The N-8031MS is a flush- or surface-mount master station designed to operate in conjunction with TOA IP Intercom Exchange and features high quality hands-free conversation. Connecting a foot switch or other external switch to the external dial input terminal permits one-touch dialing operation by way of such switches. Handset conversation can be established in conjunction with the optional RS-191.

Power Source 48 V DC (supplied from the IP intercom exchange (option))
Power Consumption 1.8 W (at rated), 2.4 W (max.)
Wiring Method 1 set of twisted pair cable
Transmission System 2 wire 160 kbps echo canceller transmission system
Signal Level Under 0 dB*
Speech Method Hands-free conversation
(Handset conversation can be established in conjunction with the RS-191(option).)
Audio Frequency Range 300 Hz - 7 kHz
Transmission Range Max. 1500 m (φ0.65 mm, Loop resistance 170 Ω)
Hands-free Speaker: 5.7 cm cone-type, 0.6 W, 8 Ω
Microphone: Omni-directional electret condenser microphone
Indication Status lamp
Line Connecting Terminal Pin header (2 pins)
External Dial Input No-voltage make contact input, open voltage: 5 V DC, short-circuit current: 1mA,
screwless connector (5 pins)
Installation Method Flush-mount/Surface-mount
Operating Temperature 0 ℃ to 40 ℃
Operating Humidity Under 90 % RH (no condensation)
Finish Panel: Stainless steel (SUS304), hairline
Dimensions 115 (W) × 254 (H) × 54.6 (D) mm
Weight 850 g
Accessory Box mounting screw (No.6-32UNC × 18) …4, Box mounting screw (M4 × 25) …4,
Removable terminal plug (2 pins, preinstalled on the unit) …1, Acoustic absorbent …1,
Handset jumper (8 pins, preinstalled on the unit) …1, Ferrite clamp …1
Option For flush-mount: Back Box YC-241
For surface-mount: Wall-mount Box YC-251
The N-8031MS is a flush- or surface-mount master station designed to operate in conjunction with TOA IP Intercom Exchange and features high quality hands-free conversation.
$535.90
Call/Emergency Switch Station
Call/Emergency Switch Station (RS-144)

The RS-144 dual button call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces. It provides Emergency (Red) and Normal (white) buttons that can be individually programmed to report to any master station based on job specification. It requires 3-conductor shielded twisted pair (STP) wiring and mounts in a standard US single gang flush or wall mount box. The optional RS-141 handset for private calling, or a 25V/1W speaker such as the PC-580RU for room announcement applications, can be connected to the call panel station

The RS-144 dual button call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces.  It provides Emergency (Red) and Normal (white) buttons that can be individually programmed to report to any master station based on job specification.
$96.50
Indoor Vandal Resistant Remote Sub-Station
Indoor Vandal Resistant Remote Sub-Station (RS-160)

The RS-160 vandal resistant single button indoor call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces. It provides a 4cm (1.57in) speaker for clear audio and a single vandal resistant metal call button with button bezel, allowing for simple call-in operation. Additionally the substation’s front faceplate is made from thick 11 gauge stainless steel stock for added durability. The call button can be programmed to report to any master station based on job specification. It requires 3-conductor shielded twisted pair (STP) wiring and mounts in a standard US dual gang flush or wall mount box.

The RS-160 vandal resistant single button indoor call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces.
$0.00
Per Page      21 - 40 of 52